This study aims to analyze the heat transfer rate, convection coefficient, and Nusselt number to changes in flow rate for each type of pipe diameter at constant heat flux and flow in the entry length region. The research was conducted using an experimental method on a 1 m long horizontal copper pipe that was fed with ordinary water with a flow rate variation of 20-160 l/h for each type of pipe …