Image of ANALISIS KETIDAKSEIMBANGAN BEBAN TERHADAP ARUS NETRAL DAN LOSSES PADA TRANSFORMATOR DISTRIBUSI LA.409 UNIT PELAKSANA PELAYANAN PELANGGAN LAHAT PT. PLN (PERSERO)























































ANALISIS KETIDAKSEIMBANGAN BEBAN TERHADAP ARUS NETRAL DAN LOSSES PADA TRANSFORMATOR DISTRIBUSI LA.409 UNIT PELAKSANA PELAYANAN PELANGGAN LAHAT PT. PLN (PERSERO)
Bookmark Share

Skripsi

ANALISIS KETIDAKSEIMBANGAN BEBAN TERHADAP ARUS NETRAL DAN LOSSES PADA TRANSFORMATOR DISTRIBUSI LA.409 UNIT PELAKSANA PELAYANAN PELANGGAN LAHAT PT. PLN (PERSERO) ANALISIS KETIDAKSEIMBANGAN BEBAN TERHADAP ARUS NETRAL DAN LOSSES PADA TRANSFORMATOR DISTRIBUSI LA.409 UNIT PELAKSANA PELAYANAN PELANGGAN LAHAT PT. PLN (PERSERO)

Prasetya, Ridho - Personal Name;

In fulfilling the demand for electrical energy, load imbalance often occurs due to the unequal loads in each phase. This load imbalance can cause the transformer's ability to decrease in serving the load. This study was conducted to determine the impact of load imbalance before and after load balancing. Load balancing in this study was implemented using the Off-Peak Load Time (LWBP) and Peak Load Time (WBP) methods. From the calculations performed on the LA.409 distribution transformer, the highest load imbalance percentage reached 40.29%, occurring on Sunday afternoon, and the lowest load imbalance percentage was 16.98%, occurring on Wednesday night. Based on the analysis, load imbalance does not correlate with neutral current because neutral current can also be caused by harmonics. However, load imbalance can cause significant losses if there is no load balancing efforts. From the calculations performed, the total network losses during the day before load balancing were 75487,439 Watts and at night were 113175,693 Watts over seven days. Meanwhile, the total network losses after load balancing during the day were 54845,571 Watts and at night were 94730,256 Watts over seven days. Keywords : Load imbalance, neutral current, losses


Availability
#
Central Library (Reference) T1479852024
T147985
Available but not for loan - Not for Loan
Detail Information
Series Title
-
Call Number
T1479852024
Publisher
Indralaya : Prodi Teknik Elektro, Fakultas Teknik Universitas Sriwijaya., 2024
Collation
xii, 80 hlm.; ilus.; tab.; 29 cm
Language
Indonesia
ISBN/ISSN
-
Classification
621.319 07
Content Type
Text
Media Type
unmediated
Carrier Type
-
Edition
-
Subject(s)
Prodi Teknik Elektro
Transformator Distribusi
Specific Detail Info
-
Statement of Responsibility
KA
Other version/related
TitleEditionLanguage
ANALISIS TEGANGAN TEMBUS PADA CAMPURAN JATROPHA OIL DAN COTTON SEED OIL SEBAGAI ISOLATOR PADA TRANSFORMATORid
ANALISA JATUH TEGANGAN TRANSFORMATOR DISTRIBUSI PADA PENYULANG DI GARDU INDUK SUNGAI KEDUKAN RAYON AMPERAid
ANALISIS PENGARUH KETIDAKSEIMBANGAN BEBAN TERHADAP ARUS NETRAL DAN RUGI – RUGI (LOSSES) PADA TRANSFORMATOR DISTRIBUSI PD.0048 P.T PLN (PERSERO) ULP AMPERA PALEMBANGid
ANALISIS PENGARUH KETIDAKSEIMBANGAN BEBAN TRANSFORMATOR DISTRIBUSI PE0028 PENYULANG SANUR PT. PLN (PERSERO) ULP KAYUAGUNGid
ANALISIS KETIDAKSEIMBANGAN BEBAN PADA TRANSFORMATOR DISTRIBUSI PA 0307 PT. PLN (PERSERO) UIWS2JB UP3 PALEMBANG ULP RIVAIid
STRATEGI KOMUNIKASI ORGANISASI DIVISI PEMASARAN DAN PELAYANAN PELANGGAN PT. PLN UP3 (UNIT PELAKSANA PELAYANAN PELANGGAN PALEMBANG) DALAM MENANGANI KELUHAN PELANGGAN PRIORITAS DI ERA PANDEMI COVID-19id
KOMPUTERISASI SISTEM INFORMASI PELAYANAN PELANGGAN DAN PELAPORAN PENJUALAN PADA TOKO BUKU PENUNTUNid
File Attachment
  • ANALISIS KETIDAKSEIMBANGAN BEBAN TERHADAP ARUS NETRAL DAN LOSSES PADA TRANSFORMATOR DISTRIBUSI LA.409 UNIT PELAKSANA PELAYANAN PELANGGAN LAHAT PT. PLN (PERSERO)
Comments

You must be logged in to post a comment

The Sriwijaya University Library
  • Information
  • Services
  • Librarian
  • Member Area

About Us

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Search

start it by typing one or more keywords for title, author or subject

Keep SLiMS Alive Want to Contribute?

© 2026 — Senayan Developer Community

Powered by SLiMS
Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search
Where do you want to share?