Image of ANALISIS BEBAN PENDINGIN DENGAN METODE COOLING LOAD TEMPERATURE DIFFERENCE (CLTD) PADA GEDUNG AUDITORIUM FAKULTAS EKONOMI UNIVERSITAS SRIWIJAYA
Bookmark Share

Skripsi

ANALISIS BEBAN PENDINGIN DENGAN METODE COOLING LOAD TEMPERATURE DIFFERENCE (CLTD) PADA GEDUNG AUDITORIUM FAKULTAS EKONOMI UNIVERSITAS SRIWIJAYA

Nasution, Aviv Ansori - Personal Name;

The cooling load is the amount ofheat energy thal needs to be removed from space cooling lo maintain the temperature within the range of acceptable. Heating and cooling loads, or "thermal burden", taking into account the construction and insulation, including fioors, walls, ceilings, and roofs. Air conditioning is the treatment of the air to set the temperature, humidity, cleanness and its distribution simultaneously in order to achieve comfortable conditions needed by people who are in a room. In addition, air conditioning can be defined a process cools the air so thal it reaches the ideal temperature and humidity. There are many factors that determine the cooling load on an air conditioning. These factors have an impact to system capacity, control, and design, as well as the placement of the air duet system, or the terminal units. For example, warm units under a window or along the outer wali can overcome the influence of low temperature from the surface-the surface. The transfer of heat through a veil of buildings affected by the type of materials used, by the geometric factors, such as size, shape, and orientation, the presence of heat sources with, and elimatie factors. The calculation of cooling load can be oblained from the ASHRAE Handbook of Fundamentals 1997. The procedures for this calculation can produce an air management system that is too large, resulting in less efficicnt in usage. With the increasing magnitude of the costs of energy consumplion then the more necd to hold system oplimization settings of the air of a building or buildings shall be calculated from the time of time dynamically. in general the cooling load of a building there are 2 kinds of sensible load and load that is latent. Sensible and latenl loads that is derived from the outside cooling load (extemal cooling load) and cooling load in (internal cooling load). To achieve the goal of this research is to analyze the engine capacity air conditioner the righl to use the auditorium so thal it feels comfortable. Find out how large the contribution each extemal and internal factors to the total cooling load. There are severai factors that affect the cooling load i.e. internal factors (roof, walls, glass, and partitions), extemal factors xvii V (residents, lighting, and appliances), ventilation and infillration. The total cooling load at extemal factors were obtained ol 110267.144 W at 16.00 to heat and internal load of sensibly 84647.06 W for heat sensible and latent heat to 35350 W. Ventilation load on IE of heat for sensibel 30996 W and W for latent heat 101136. Calculation Of the children are then obtained a load of coolant the building of the auditorium of the Facuity of Economics University of Sriwijaya are amounting to 380516.0142 W or 1298374.5341 Btu/h. So we get the air conditioning capacity for the building of the auditorium is 108.198 TR or 144.26 PK. 10 Keywords : Cooling load temperature difference, CLTD, latent, sensible.


Availability
#
Central Library (References) T1825622019
T182562
Available but not for loan - Not for Loan
Detail Information
Series Title
-
Call Number
T1825622019
Publisher
Inderalaya : Prodi Teknik Mesin, Fakultas Teknik Universitas Sriwijaya., 2019
Collation
xxiii, 57 hlm. : ilus. ; tab. ; 28 cm
Language
Indonesia
ISBN/ISSN
-
Classification
697.907
Content Type
Text
Media Type
unmediated
Carrier Type
other (computer)
Edition
-
Subject(s)
Prodi Teknik Mesin
Cooling Load Temperature Difference
Specific Detail Info
-
Statement of Responsibility
DS
Other version/related
TitleEditionLanguage
ANALISIS WATER COOLING SYSTEM UNTUK MENURUNKAN TEMPERATURE LOSSES PADA PANEL SURYA POLYCRYSTALLINE 50 WPid
MODEL DAN ANALISIS COOLING TECHNIQUE MENGGUNAKAN DC FAN DAN PERFORATED ALUMINIUM PLATE PADA PHOTOVOLTAIC JENIS POLLYCRYSTALINE 50 WP-id
File Attachment
  • ANALISIS BEBAN PENDINGIN DENGAN METODE COOLING LOAD TEMPERATURE DIFFERENCE (CLTD) PADA GEDUNG AUDITORIUM FAKULTAS EKONOMI UNIVERSITAS SRIWIJAYA
Comments

You must be logged in to post a comment

The Sriwijaya University Library
  • Information
  • Services
  • Librarian
  • Member Area

About Us

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Search

start it by typing one or more keywords for title, author or subject

Keep SLiMS Alive Want to Contribute?

© 2026 — Senayan Developer Community

Powered by SLiMS
Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search
Where do you want to share?