This research aims to evaluate the performance of oil and gas production at well FN-06, which operates using an Electric Submersible Pump (ESP) in the working area of PetroChina International Jabung Ltd. Well FN-06 uses an ESP pump type QN30/48 Hz at a depth of 6765 ft and produces a production rate of 420 BFPD with a pump efficiency of only 25%. This low efficiency is caused by the pump operat…